Product Description
XL 640 is a fully automated biochemistry analyzer with a throughput of 640 tests per hour. It is a dependable, powerful and robust analyzer to keep up with the heavy demands of everyday. XL 640 is designed to operate smoothly over the long haul and to deliver consistent quality report. XL 640 provides innovative solutions that meet the high productivity demands of laboratories having heavy testing pressure. It is equipped with excellent features which yield higher productivity, increased efficiency and greater cost savings for the laboratory. It has got the continuous loading facility for samples which make XL 640 the most dependable partner.
Product Features:
- Throughput of 400 tests/ hour (Photometric) and 640 tests/hour with ISE
- On-board cooling for reagents
- On-board Laundry
- Seperate probes for reagent R1 & R2 and dedicated probe for sample
- Clot detection for sample probe
- 72 permanant hard glass cuvettes
- Automatic dilution for high abnormal samples & Auto Rerun facility
- Extensive QC Programmes with Levy Jennings Curve & QC rules. Automatic calculation for Mean SD & CV%
- Direct loading for primary tubes
- Bi-directional connectivity
Product Applications:
- Substrates: Albumin, Bicarbonate, Bilirubin Direct, Bilirubin Total, Calcium, Cholesterol, Creatinine, Glucose, Phosphorus, Total Protein, Triglycerides, Urinary Protein, Urea, Uric Acid, Phospholipids, Microprotein, Myoglobin, Microalbumin
- Enzymes: ACP, ALP, Amylase, CHE, CK, CK-MB, GGT, GOT (AST), GPT (ALT), HBDH, LDH
- ISE: Sodium, Potassium, Chloride
- Immunoturbidimetric Assays: ApoA1, ApoB, ASO, CRP, Ferritin, HbA1c,RF, Transferrin,HDL Cholesterol, LDL Cholesterol
Photometry: - Multi-wavelength diffraction grating with 12 wavelengths (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700, 750 nm)
Calibration: - K-Factor, Linear (1, 2 and multipoint), 4P and 5P Logit-log, cubic spline, exponential. On board serial dilution for calibrator.
Power Requirement:Sample Pipetting: - 2-70 micro L (adjustable in 0.1 micro L step) for biochemistry, 70 micro L (fixed) for ISE capacitance probe with level sensing, vertical obstruction detection, clog deduction and serum indices.
Auto Rerun: - Repeat with same, increased or decreased volume (upto 1:150)
Sample Tubes/Cups: - Primary tubes of 5 ml, 7 ml, 10 ml and sample cups.
Reagent Pipetting: - R1: 60 - 300 micro L (adjustable in 1 micro L), R2: 0 or 10 - 300 micro L (adjustable in 1 micro L), R3: 0 or 10 - 300 micro L (adjustable in 1 micro L)
- Capacitance probe with liquid level sensing and vertical obstruction detection.
Advanced Throughput and FlexibilityThe XL 640 provides unmatched productivity with its ability to process up to 640 photometric tests per hour, or 1280 when equipped with the optional ISE module. Its flexible discrete, random access technology allows for simultaneous handling of multiple sample types like serum, plasma, urine, and CSF, catering to diverse clinical biochemistry requirements and emergency STAT testing demands.
Superior Efficiency with Automated FeaturesEfficient workflow is achieved through features such as automatic reagent and sample loading, auto-washing reusable cuvettes, and built-in clot detection with alerts. The analyzer integrates automatic, programmable cleaning protocols, reducing hands-on time for users. The large interactive touchscreen and bidirectional LIS connectivity further streamline operations, supporting real-time data exchange and ease of use.
Robust Quality Control and SafetyMulti-level automatic calibration, integrated QC management, and reliable curve-fit options ensure precise results. Barcode systems for both reagents and samples minimize human error, while an alert-driven alarm system and low water and noise consumption enhance laboratory safety and comfort. Engineered with industrial-grade, corrosion-resistant materials, the XL 640 guarantees durability and dependable performance.
FAQ's of Transasia XL 640 Fully Automated Biochemistry Analyzer:
Q: How does the Transasia XL 640 manage different sample types during analysis?
A: The XL 640 is designed to process various clinical sample types, including serum, plasma, urine, and cerebrospinal fluid (CSF). Its discrete, random-access functionality allows easy switching between these samples, supporting routine and specialized biochemistry tests with high accuracy and flexibility.
Q: What procedures are involved in maintaining the Transasia XL 640 analyzer?
A: Maintenance is largely automated, with programmable cleaning protocols for crucial components like cuvettes and probes. The analyzer features auto-washing for reusable cuvettes and prompts for user intervention when periodic manual checks or cleaning are required, ensuring optimal performance with minimal downtime.
Q: When should laboratories use the XL 640's emergency STAT facility?
A: The emergency STAT facility is best utilized when rapid test turnaround is critical, such as for urgent clinical assessments. This feature allows high-priority samples to be processed immediately, ensuring timely results for patient management in acute care settings.
Q: Where is the ideal environment to install the Transasia XL 640?
A: The analyzer should be installed in a well-ventilated, dry laboratory environment within a temperature range of 15-30C and humidity below 80% (non-condensing). Positioning the unit in such controlled conditions ensures reliable operation and prolongs equipment life.
Q: What are the benefits of the built-in quality control and barcode systems?
A: Integrated QC management provides ongoing validation of analytical accuracy, while the barcode system for both samples and reagents streamlines workflow, reduces manual errors, and facilitates efficient traceability, ultimately improving both reliability and laboratory productivity.
Q: How does the analyzer ensure accurate and consistent calibration?
A: The XL 640 offers automatic, multi-level calibration with various curve-fit options, enhancing analytical consistency across different assays. Regular, programmed calibration cycles ensure that test results remain precise and reliable, meeting clinical quality standards.