Product Description
Product description
34 parameters including RET%, RET#, IRF, and research parameters;
Up to 60 T/H;
Laser light multi-dimensional cellclassification;
Double mode for WBC counting (ImpedanceCount and Optical Count);
Resistant RBC mode;
WBC 5-diff with sheath reagent only;
Technical Details 
Accurate and Efficient Blood Cell AnalysisThe Urit-5160 5-part diff hematology analyzer combines laser flow cytometry and impedance methods to deliver quick, reliable complete blood counts. With high accuracy rates-over 97% for WBC and 98% for RBC and PLT-and a comprehensive flagging system, clinicians can trust the results for precise diagnosis and patient care. Its 29 reportable parameters provide a full hematological profile with each test.
High Throughput with User-Friendly DesignWith a capacity to process up to 60 samples per hour and both manual and automatic sampling modes, the Urit-5160 enhances laboratory efficiency. Its 10.4-inch touch display, built-in thermal printer, and multilingual support enable intuitive operation, while automated startup, shutdown, and cleaning simplify daily maintenance. Sturdy construction ensures long-term durability in busy clinical settings.
Comprehensive Data Management and ConnectivityEquipped with storage for 100,000 results-including graphics-the Urit-5160 offers versatile connectivity through USB and LAN ports. Optional barcode integration streamlines sample identification, and an internal QC program supports multi-level quality control. The system is designed for seamless operation and integration within modern laboratory environments.
FAQ's of Urit-5160 5 -part Diff Hematology analyzer:
Q: How does the Urit-5160 hematology analyzer ensure accurate leukocyte classification?
A: The Urit-5160 employs a combination of laser flow cytometry and impedance methods, providing precise differentiation and counting of WBCs. Its advanced technology and multi-level QC controls maintain accuracy rates of over 97% for WBCs, ensuring reliable clinical results.
Q: What is the process for operating the Urit-5160, and what sampling modes are available?
A: Operation is user-friendly via the 10.4-inch touchscreen display. Users can choose between manual mode for individual tests or the auto loader for batch processing, depending on workload requirements. Automated maintenance protocols further simplify daily operation.
Q: When should calibration or quality control be performed on the Urit-5160?
A: The analyzer supports both automatic and manual calibration. Regular QC should be performed as recommended in clinical guidelines and whenever there is a batch change, maintenance, or unexpected test result discrepancies to ensure continued accuracy.
Q: Where can the Urit-5160 be installed, and what are the storage requirements?
A: This bench-top analyzer is designed for clinical laboratory environments. It should be placed on a sturdy workstation in a dry, dust-free area. As it is not portable or wall-mounted, ensure adequate space for its dimensions (430 680 460 mm) and power supply (AC 100-240 V, 50/60 Hz).
Q: What are the main benefits of using the Urit-5160 for CBC analysis?
A: Benefits include high throughput (up to 60 samples/hour), comprehensive 5-part leukocyte differentiation, extensive data storage, intuitive operation, reliable flagging, and low carryover rate (0.5%). These features support efficient workflow and accurate diagnostics in clinical laboratories.
Q: How does the Urit-5160 support data management and connectivity?
A: The system stores up to 100,000 results with graphics and connects easily via USB and LAN. Its built-in thermal printer allows immediate record printing, and an optional barcode reader enhances sample tracking and workflow efficiency.
Q: What maintenance features are included with the Urit-5160 analyzer?
A: Automated daily startup, shutdown, and cleaning routines are built-in to reduce manual maintenance. This automation minimizes user intervention requirements, extends instrument longevity, and ensures consistent performance.