• email rajbiosis@yahoo.in

  • email08045816368

Change Language

Finecare Probnp Fluorescence Immunoassay

520 INR/Kit

Product Details:

  • Shelf Life 18 Months (Test kit)
  • Features Rapid results, easy operation, high sensitivity, compact design
  • Display Type LCD Touchscreen
  • Accuracy High (as per clinical standards)
  • Usage Type Laboratory and Point-of-care
  • Function Detection of NT-proBNP marker for heart failure
  • Instruments Type Analyzer
  • Click to view more
X

Finecare Probnp Fluorescence Immunoassay Price And Quantity

  • 520 INR/Kit
  • 2 Box

Finecare Probnp Fluorescence Immunoassay Product Specifications

  • No
  • Laboratory and Point-of-care
  • Detection of NT-proBNP marker for heart failure
  • Quantitative determination of ProBNP (NT-proBNP) in human blood
  • Yes
  • New
  • 18 Months (Test kit)
  • Rapid results, easy operation, high sensitivity, compact design
  • Approx. 3.5 kg
  • LCD Touchscreen
  • AC power supply
  • High (as per clinical standards)
  • Fluorescence Immunoassay
  • Automatic
  • <50W
  • Fluorescence Immunoassay Analyzer
  • Yes
  • Plastic, Electronic Components
  • 50/60 Hz
  • Low
  • Approx. 260mm x 220mm x 130mm
  • Analyzer
  • 100-240V, 50/60Hz
  • 535000 pg/mL (NT-proBNP)
  • Store at 2-30C, dry place
  • White

Finecare Probnp Fluorescence Immunoassay Trade Information

  • JAIPUR
  • Cash in Advance (CID), Cash Advance (CA), Telegraphic Transfer (T/T), Cheque
  • 10 Days
  • Contact us for information regarding our sample policy
  • Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa
  • All India

Product Description

  • The Finecare BNP Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare FIA System for quantitative determination of Brain Natriuretic Peptides (BNP) in human whole blood or plasma. This test is used as an aid to predict the risk of heart failure.
  • STORAGE AND STABILITY1. Store the test kit at 4 30 up to the expiration date printed on package.

    2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing.

    3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Technical Details 



Advanced Heart Failure Diagnosis

The Finecare Probnp Fluorescence Immunoassay Analyzer provides a streamlined approach for detecting NT-proBNP markers, supporting clinicians in diagnosing heart failure with precision. Its rapid, quantitative analysis aids timely medical decisions, vital in both emergency and screening settings.


Effortless Workflow and Operation

With automatic calibration, real-time operation, and an intuitive LCD touchscreen, the analyzer simplifies workflow for laboratory and point-of-care staff. Its portable and compact design, coupled with low power consumption, makes it convenient for use in various healthcare environments.


Reliable Performance and Data Management

This analyzer features high accuracy within a measurement range of 5-35,000 pg/mL for NT-proBNP. Data can be easily output via USB or printer, ensuring seamless integration into laboratory records and facilitating accurate patient monitoring over time.

FAQ's of Finecare Probnp Fluorescence Immunoassay:


Q: How does the Finecare Probnp Fluorescence Immunoassay Analyzer detect NT-proBNP levels?

A: The analyzer uses fluorescence immunochromatographic technology, which quantitatively detects NT-proBNP markers in whole blood, plasma, or serum samples. This method provides high sensitivity and precise results essential for heart failure diagnosis.

Q: What is the recommended process for conducting a test using this analyzer?

A: Collect a sample (whole blood, plasma, or serum), apply it to the test kit, and insert it into the analyzer. The device automatically calibrates and processes the sample, delivering results on the touchscreen display in about 15 minutes.

Q: When should NT-proBNP testing be performed using the Finecare analyzer?

A: It is recommended for use during initial heart failure screening, diagnosis in symptomatic patients, and ongoing monitoring of individuals with known or suspected cardiac issues in both laboratory and point-of-care settings.

Q: Where can this analyzer be deployed for optimal use?

A: Its compact, portable design suits hospital laboratories, emergency rooms, clinics, and point-of-care testing sites. It does not require wall mounting, facilitating flexible placement wherever heart failure testing is necessary.

Q: What are the main benefits of using this device over traditional methods?

A: This analyzer offers rapid results, high sensitivity, automatic calibration, and real-time operation. Its user-friendly interface and USB/printer connectivity enhance workflow efficiency, supporting accurate, timely decision-making in clinical practice.

Q: How should the test kit and analyzer be stored to maintain performance?

A: Store the test kits in a dry place at a temperature between 2-30C. The analyzer should also be kept in a controlled environment within this range and plugged into an AC power supply for optimal function and shelf life.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Immunoassay Reagents' category



Back to top